While working on the house next door we spotted this masterpiece of crappy plumbing. Back in 1970 this would have sold as modern art!
Technically there are so many problems with this it’s hard to count them all.
So for fun let’s follow the flow of water from this condensing boiler through to the main waste pipe.
The condensing boiler, as a by-product of squeezing extra heat from the same volume of gas that would be wasted in a ‘normal’ boiler produce condensation within the boiler. Some of that moisture can be seen in the plume (the long trail of what looks like steam coming from modern flues). Some of that moisture trickles back into the boiler and must be removed or the boiler would drown in it’s own waste!
The waste is gathered in various ways depending on the manufacturer but in most cases flows down into the boiler and out through a 21.5mm overflow pipe. The rules how to pipe up condensation pipe work are well published so there should be no misconception as to how to do it. In the case of our Cowboy Of The Week Award winner several issues can be seen without having to look closely.
So the water flows from the boiler to the outside of the house into unclipped push fit 21.5mm waste pipe with TWO elbows, dribbles loosely into a 32mm elbow which then runs approximately 16 inches downhill from start to finish through an unclipped waste pipe which has bent under its own weight, the flow then turns 90 degrees and flows UPHILL about 8 inches and then dribbles down the wall.
WOW! The safe bet here is that this boiler was installed by a non-CORGI registered cowboy or home owner or a mate who also did the same type of quality work on the electrics and gas as well. Scary!
![]()